Product aliases
Alkyd magnetic paint, alkyd top coat, alkyd paint, alkyd anticorrosive paint, alkyd anticorrosive top coat, alkyd magnetic top coat.
Basic parameters
English name of product | Alkyd paint |
Chinese name of product | Alkyd paint |
Dangerous Goods No. | 33646 |
UN No. | 1263 |
Organic solvent volatility | 64 standard metre³. |
Brand | Jinhui Paint |
Model No. | C52-5-1 |
Colour | Colourful |
Mixing ratio | One-component |
Appearance | Smooth surface |
Product composition
Alkyd paint is composed of alkyd resin, additives, No.200 solvent gasoline and mixed solvent, and catalyst.
Surface Treatment
● Steel surface sandblasting treatment to Sa2.5 grade, surface roughness 30um-75um.
● Electrical tools to remove rust to St3 grade.
Pre-course Matching
Alkyd primer, alkyd intermediate paint.
Characteristics
- Strong adhesion, good mechanical properties.
- Strong filling ability.
- High pigment content, good sanding performance.
- Good weather resistance, gloss and hardness.
- Good adhesion to metal and wood, and some water resistance and salt water resistance.
- Tough paint film, good sealing, excellent anti-rust performance, can withstand the impact of temperature difference.
- Good construction performance.
- The paint film is anti-chalking, with good protection performance, good light and colour retention, bright colour and good durability.
Usage
Suitable for indoor and outdoor metal surface and wood surface protection and decoration, is a general-purpose paint, widely used in construction, machinery, vehicles and a variety of decorative industries.
Technical parameters: GB/T 25251-2010
- Status in the container: no hard lumps after stirring and mixing, in a homogeneous state.
- Fineness: ≤40um (standard index: GB/T6753.1-2007)
- Non-volatile matter content: ≥50% (standard index: GB/T1725-2007)
- Water resistance: 8h without cracking, blistering or peeling (Standard index: GB/T9274-88)
- Salt water resistance: 3% NaCl, 48h without cracking, blistering and peeling (Standard index: GB/T9274-88)
- Drying time: surface drying ≤ 8h, solid drying ≤ 24h (standard index: GB/T1728-79)
Paint construction
- After opening the barrel, it must be stirred evenly, left to stand and mature for 30min, then add appropriate amount of thinner and adjust to the construction viscosity.
- Diluent: special diluent for alkyd series.
- Airless spraying: Dilution amount is 0-5% (by weight ratio of paint), nozzle calibre is 0.4mm-0.5mm, spraying pressure is 20MPa-25MPa (200kg/cm²-250kg/cm²).
- Air spraying: Dilution amount is 10-15% (by weight ratio of paint), nozzle calibre is 1.5mm-2.0mm, spraying pressure is 0.3MPa-0.4MPa (3kg/cm²-4kg/cm²).
- Roller coating: Dilution amount is 5-10% (by paint weight ratio)
Transport storage
- The product should be stored in a cool and ventilated place, protected from direct sunlight, and isolated from sources of ignition, away from heat sources in the warehouse.
- Products should be prevented from rain, sunlight exposure, avoid collision when transported, and should comply with the relevant regulations of the traffic department.
Customer FAQ
● Is it easy to paint white and light coloured topcoat after applying Iron Red anti-rust?
A: No, it is not easy. Two more coats of topcoat are needed.
● Can the topcoat be applied on plastic, aluminium and galvanised surfaces?
A: Conventional alkyd enamels cannot be applied to the above surfaces.
Attention
- In the high temperature season construction, easy to dry spray, in order to avoid dry spray can be adjusted with thinner until not dry spray.
- This product should be used by professional painting operators according to the instructions on the product package or this manual.
- All coating and use of this product must be carried out in accordance with all relevant health, safety and environmental regulations and standards.
- If in doubt as to whether this product should be used, please contact our technical service department for details.
Safety precautions
- The construction site should be well ventilated and painters should wear glasses, gloves, masks, etc. to avoid skin contact and inhalation of paint mist.
- Smoke and fire are strictly prohibited at the construction site.