Basic parameters

Product English name  Magnetic alkyd paint
Product Chinese name  Alkyd Magnetic Top Coat
Dangerous Goods No.  33646
UN No.  1263
Organic solvent volatility  64 standard metre³.
Brand  Jinhui Paint
Model No.  C52-5-6
Colour  Colourful
Mixing ratio  Single component
Appearance  Smooth surface

Product composition

  • Alkyd magnetic top coat is a magnetic top coat composed of alkyd resin, additives, No.200 solvent gasoline and mixed solvents, and catalytic agent.

Technical parameters: GB/T 25251-2010

  • Status in the container: no hard lumps after stirring and mixing, in a homogeneous state
  • Fineness: ≤40um (standard index: GB/T6753.1-2007)
  • Non-volatile matter content: ≥50% (Standard index: GB/T1725-2007)
  • Water resistance: 8h without cracking, blistering or peeling (Standard index: GB/T9274-88)
  • Salt water resistance: 3% NaCl, 48h without cracking, blistering and peeling (Standard index: GB/T9274-88)
  • Drying time: surface drying ≤ 8h, solid drying ≤ 24h (standard index: GB/T1728-79)

Surface treatment

  • Steel surface sandblasting treatment to Sa2.5 grade, surface roughness 30um-75um.
  • Electrical tools descaling to St3 grade.

Front course matching

  • Alkyd primer, alkyd intermediate paint.

Usage

  • Suitable for steel surface, machinery surface, pipeline surface, equipment surface, wood surface; suitable for indoor and outdoor metal surface and wood surface protection and decoration, is a general-purpose paint, widely used in construction, machinery, vehicles and various decorative industries.
Alkyd-Magnetic-Top-Coat-application

Painting construction

  • After opening the barrel, it must be stirred evenly, left to stand, and after maturing for 30min, add appropriate amount of thinner and adjust to the construction viscosity.
  • Diluent: special diluent for alkyd series.
  • Airless spraying: Dilution amount is 0-5% (by weight ratio of paint), nozzle calibre is 0.4mm-0.5mm, spraying pressure is 20MPa-25MPa (200kg/cm²-250kg/cm²).
  • Air spraying: Dilution amount is 10-15% (by weight ratio of paint), nozzle calibre is 1.5mm-2.0mm, spraying pressure is 0.3MPa-0.4MPa (3kg/cm²-4kg/cm²).
  • Roller coating: Dilution amount is 5-10% (in terms of paint weight ratio).
  • Alkyd primer, alkyd intermediate paint.

Precautions

  • In the high temperature season construction, easy to dry spray, in order to avoid dry spray can be adjusted with thinner until not dry spray.
  • This product should be used by professional painting operators according to the instructions on the product package or this manual.
  • All coating and use of this product must be carried out in accordance with all relevant health, safety and environmental regulations and standards.
  • If in doubt as to whether this product should be used, please contact our technical service department for details.
  • Alkyd primer, alkyd intermediate paint.

Transport Storage

  • The product should be stored in a cool and ventilated place, protected from direct sunlight, and isolated from sources of ignition and kept away from heat sources in a warehouse.
  • Products should be protected from rain, sunlight and collision when transported, and should comply with the relevant regulations of the traffic department.

Safety Protection

  • The construction site should have good ventilation facilities, and painters should wear glasses, gloves, masks, etc. to avoid skin contact and inhalation of paint mist.
  • Smoke and fire are strictly prohibited at the construction site.

Customer's Frequently Asked Questions

faq

● Is it easy to paint white and light-coloured topcoat after applying Iron Red anti-rust?
A: No, it is not easy, you need to apply two more coats of topcoat.

● Can the topcoat be applied on plastic, aluminium and galvanised surfaces?
A: Conventional alkyd enamels cannot be applied to the above surfaces.