page_head_banner

Solutions

Alkyd Anti-corrosion Coating

Product aliases

  • Alkyd paints, alkyd finishes, alkyd coatings, alkyd magnetic paints, alkyd anti-corrosion finishes, alkyd magnetic finishes.

Basic parameters

Product English Name  Alkyd anticorrosive coatings
Product Chinese Name  Alkyd anticorrosive coatings
Dangerous Goods No.  33646
UN No.  1263
Organic solvent volatility  64 standard metre³.
Brand  Jinhui Coatings
Model No.  C52-5-4
Colour  Colourful
Mixing ratio  One-component
Appearance  Smooth surface

Product composition

  • Alkyd anticorrosive coatings are anticorrosive coatings composed of alkyd resin, additives, No.200 solvent gasoline and mixed solvents, and catalytic agent.

Characteristics

  • Paint film anti-chalking, good protection performance, good light retention and colour retention, bright colour, good durability.
  • Strong adhesion, good mechanical properties.
  • Strong filling ability.
  • High pigment content, good sanding performance.
  • Good weather resistance, gloss and hardness.
  • Good adhesion to metal and wood, and some water resistance and salt water resistance.
  • Tough paint film, good sealing, excellent anti-rust performance, can withstand the impact of temperature difference.
  • Good construction performance.

Usage

  • Suitable for steel surface, machinery surface, pipeline surface, equipment surface, wood surface; also suitable for indoor and outdoor metal surface and wood surface protection and decoration, is a general-purpose paint, widely used in construction, machinery, vehicles and various decorative industries.
Alkyd-Anti-corrosion-Coating-application

Technical parameters: GB/T 25251-2010

  • Status in the container: no hard lumps after stirring and mixing, in a homogeneous state.
  • Fineness: ≤40um (standard index: GB/T6753.1-2007)
  • Non-volatile matter content: ≥50% (standard index: GB/T1725-2007)
  • Water resistance: 8h without cracking, blistering or peeling (Standard index: GB/T9274-88)
  • Salt water resistance: 3% NaCl, 48h without cracking, blistering and peeling (Standard index: GB/T9274-88)
  • Drying time: surface drying ≤ 8h, solid drying ≤ 24h (standard index: GB/T1728-79)

Construction parameters

Recommended film thickness  60-80um
Theoretical dosage  about 120g/m² (35um dry film, excluding loss)
Recommended number of coats  2~3
Storage temperature  -10~40℃
Construction temperature  5~40℃.
Trial period  6h
Construction method  Brushing, air spraying, rolling can be.
Coating interval

 

 

 Substrate temperature ℃ 5-10 15-20 25-30
 Shorter interval h 48 24 12
 The longer interval should not exceed 7 days.
The substrate temperature must be higher than the dew point by more than 3℃. When the substrate temperature is lower than 5℃, the paint film will not be cured and it is not suitable for construction.

Paint construction

  • After opening the barrel, it must be stirred evenly, left to stand and mature for 30min, then add appropriate amount of thinner and adjust to the construction viscosity.
  • Diluent: special diluent for alkyd series.
  • Airless spraying: Dilution amount is 0-5% (by weight ratio of paint), nozzle calibre is 0.4mm-0.5mm, spraying pressure is 20MPa-25MPa (200kg/cm²-250kg/cm²).
  • Air spraying: Dilution amount is 10-15% (by weight ratio of paint), nozzle calibre is 1.5mm-2.0mm, spraying pressure is 0.3MPa-0.4MPa (3kg/cm²-4kg/cm²).
  • Roller coating: Dilution amount is 5-10% (in terms of paint weight ratio).

Precautions

  • In the high temperature season construction, easy to dry spray, in order to avoid dry spray can be adjusted with thinner until not dry spray.
  • This product should be used by professional painting operators according to the instructions on the product package or this manual.
  • All coating and use of this product must be carried out in accordance with all relevant health, safety and environmental regulations and standards.
  • If in doubt as to whether or not to use this product, please contact our technical service department for details.

Packaging

  • 25kg drum

Transport and storage

  • The product should be stored in a cool and ventilated place, prevented from direct sunlight, and isolated from sources of ignition, away from heat sources in the warehouse.
  • When transporting the product, it should be prevented from rain, sunlight exposure, avoid collision, and should comply with the relevant regulations of the traffic department.

Safety Protection

  • The construction site should have good ventilation facilities, and painters should wear glasses, gloves, masks, etc. to avoid skin contact and inhalation of paint mist.
  • Construction site is strictly prohibited fireworks.

Customer's Frequently Asked Questions

faq

● Is it easy to paint white and light coloured topcoat after applying Iron Red anti-rust?
A: No, it is not easy and requires two more coats of topcoat.

● Can the topcoat be applied to plastic, aluminium and galvanised surfaces?
A: Conventional alkyd enamels cannot be applied to these surfaces.